Description
SPECIFICATION FEATURES
Construction
- Solid cast aluminum walls between the housing and arm create a thermal barrier between the optical and electrical
- Molded silicone gaskets throughout to insure sealing between the two compartments and ingress
- Suitable for applications requiring 3G testing prescribed by ANSI C136.31
Optics
- Light engines are available in standard 4000 K and 5000 K (70 CRI)
- Scalable Lumen Packages from 3,750 to 13,900 Lumens
- Tempered UV coated flat lens provide outstanding performance, uniformity and glare control.
Electrical
- Universal 120-277 VAC or 347-480 VAC input voltage
- Externally mounted emergency battery backup for operation in an ambient temperature ranging from -40℃ to 45℃(-40℉ to 113℉)
Lifespan
- Estimated 100,000-hour LED lifespan based on IES LM-80 results and TM-21 calculations
Warranty
- Five-year
DIMENSIONS
unit: mm/inch
PERFORMANCE DATA
SYSTEM WATTS |
VOLTAGE |
CRI |
LUMENS (4000K) | LPW (4000K) | LUMENS (5000K) | LPW (5000K) |
27W | 120-277V | 70 | 3750lm | 139 lm/W | 3800lm | 141 lm/W |
40W | 120-277V/347-480V | 70 | 5350lm | 134 lm/W | 5400lm | 135 lm/W |
70W | 120-277V/347-480V | 70 | 9550lm | 136 lm/W | 9600lm | 137 lm/W |
100W | 120-277V | 70 | 13850lm | 139 lm/W | 13900lm | 139 lm/W |
ORDERING GUIDE Example:MWP09 40W 27V XXK Y Y Y Y Y | |||||||||
Fixture Type | Wattage | Voltage | CCT | Finish | Photocell (Option) | Sensor (Option) | Dimmable (Option) | Emergency Battery (Option) | Internal Code |
MFD08 |
27 27W |
27V 120-277V |
40K 4000K |
D Dark Bronze |
P0 120-277V Photocell |
M With 120-277V Sensor |
D 1-10V DIM |
B Emergency Battery |
Blank |
Flood Light series | 40 40W | 48V 347-480V | 50K 5000K | B Black | Blank Without Photocell | Blank Without Sensor | Blank NO DIM | Blank Without Emergency Battery | Alphanumeric |
70 70W | W White | ||||||||
100 100W |
Note:
27W is limited to 120-277V input voltage and non dimming.
100W is limited to 120-277V input voltage and
70W with dimming and non dimming
Only the DIM has emergency batter options.
DLC Model NO.
SYSTEM WATTS | VOLTAGE | CCT | DLC NO. | DLC Classification |
27W |
120-277V |
4000K | MWP0927W27V40K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium |
5000K | MWP0927W27V50K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium | ||
40W |
120-277V |
4000K | MWP0940W27V40K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium |
5000K | MWP0940W27V50K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium | ||
347-480V |
4000K | MWP0940W48V40K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | |
5000K | MWP0940W48V50K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | ||
70W |
120-277V |
4000K | MWP0970W27V40K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium |
5000K | MWP0970W27V50K[D,B,W,SG][Blank,P0][Blank,M][Blank,0-9 or A-Z or a-z] | Premium | ||
4000K | MWP0970W27V40K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | ||
5000K | MWP0970W27V50K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | ||
347-480V |
4000K | MWP0970W48V40K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | |
5000K | MWP0970W48V50K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium | ||
100W |
120-277V |
4000K | MWP09100W27V40K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium |
5000K | MWP09100W27V50K[D,B,W,SG][Blank,P0][Blank,M]D[Blank,B][Blank,0-9 or A-Z or a-z] | Premium |
DESCRIPTION
The MWP09 appearance is complementary with the area/site luminaire bringing a modern architectural style to wall mounted lighting applications. The optics are specifically designed to maximize light in the desired area making it the smart choice for building-mounted doorway and pathway illumination on nearly any type of facility. To meet local requirements, emergency battery backup and a variety of motion sensor options are available.